ELECTRIC SHOCK - GROUND FAULT IN FOOD WARMER
Investigation abstract
An employee was filling a steam table with warm food. The strain relief on the f ood warmer's power supply cord was no longer working as intended. Consequently, the equipment grounding conductor and the grounded neutral conductor had pulled away from their screws in the cord's attachment plug. The equipment grounding co nductor was apparently contacting the ungrounded circuit conductor, energizing t he case of the food warmer. The employee filling the food warmer was electrocute d when he touched it.