105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14214324

BURN,E GI II,ELEC PROTECT EQUIP,ELECTRICAL,TEST EQUIPMENT,ELECTRIC SHOCK,MICROWAVE OVEN

Event
BURN,E GI II,ELEC PROTECT EQUIP,ELECTRICAL,TEST EQUIPMENT,ELECTRIC SHOCK,MICROWAVE OVEN
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14214324
Report ID
454714

Event description

ELECTRIC SHOCK & BURN - DIRECT CONTACT WITH LIVE PARTS

Investigation abstract

AN ELECTRONIC EQUIPMENT REPAIRER HAD SERVICED A 240-VOLT LITTON COMMERCIAL MICRO WAVE OVEN (MODEL NUMBER 70-80), AND HE WAS PERFORMING A HIGH VOLTAGE TEST ON IT. HE WAS USING A NEW EMCO PHV-1 HIGH VOLTAGE PROBE THAT HAD BEEN PURCHASED BY THE EMPLOYER 1 OR 2 DAYS EARLIER. THE REPAIRER WAS WORKING ALONE, BUT THERE WAS ANO THER EMPLOYEE IN THE VICINITY. THE REPAIRER MADE TWO ATTEMPTS TO MEASURE VOLTAGE , BUT THE METER DID NOT REGISTER ANY VOLTAGE. ON THE THIRD ATTEMPT, HE RECEIVED AN ELECTRIC SHOCK AND YELLED TO HIS COWORKER TO "GET ME OFF OF THIS". THE EMPLOY EE RECEIVED BURNS ON BOTH HANDS; HE HAD BEEN HOLDING THE GROUNDED METER IN HIS R IGHT HAND AND HAD APPARENTLY CONTACTED AN ENERGIZED PART WITH HIS LEFT HAND.

Victim

  1. #1 Hospitalized Age 29 M

    Nature of injury
    10
    Part of body
    12
    Event type
    13
    Source
    15
    Occupation code
    523
    Human factor
    14
    Environmental factor
    18
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.