105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14225064

PULL BACK DEVICE,DIE,AMPUTATED,POWER PRESS,FINGER,FOOT CONTROL,BOLT,HAND

Event
PULL BACK DEVICE,DIE,AMPUTATED,POWER PRESS,FINGER,FOOT CONTROL,BOLT,HAND
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14225064
Report ID
355119

Event description

EMPLOYEE'S FINGERS AMPUTATED WHEN CAUGHT IN POWER PRESS

Investigation abstract

At approximately 7:30 a.m., on April 24, 1987, Employee #1 was being trained to ft pull back device too long to pull the hand out of the dies. operate a full revolution Minster power press Serial Number 10-4-4585. The power press was operated by a foot control and equipped with pull back devices. The s upervisor of Employee #1 adjusted the pull back devices to fit Employee # 1. Whe n placing a part in the press, Employee # 1 pushed the foot switch and the press cycled. The pull back device of left hand did not pull the hand out, causing pa rtial amputation of four fingers on the left hand. The inspection of the press c onducted after the accident found that the bolt holding back frame to the press broke. This allowed the frame to drop or pull away from the press, making the le

Victim

  1. #1 Hospitalized Age 21 M

    Nature of injury
    1
    Part of body
    10
    Event type
    2
    Source
    26
    Occupation code
    706
    Human factor
    12
    Environmental factor
    3
    Task assigned
    1