105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14299457

CHEST,LEAK,THROAT,INSTALLING,INADEQUATE MAINT,WORK RULES,INHALATION,TOXIC FUMES,ACCIDENTAL DISCHARGE

Event
CHEST,LEAK,THROAT,INSTALLING,INADEQUATE MAINT,WORK RULES,INHALATION,TOXIC FUMES,ACCIDENTAL DISCHARGE
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14299457
Report ID
352450

Event description

Employee inhales to toxic gas

Investigation abstract

Employee #1 was about 5 to 10 feet away from a leak that occurred during the ins tallation of silicon tetra fluoride gas to the plasma enhanced chemical vapor de position system. The gas seeped through the connection between the shut-off valv e and the regulator because of stripped threads on the pipe nipple. It was dissi pated throughout the room toward Employee #1 by a cooling fan on an instrument b ehind the leak. The fan was blowing air past the cylinder. Employee #1 inhaled s ome of the toxic gas and complained of a burning sensation in his throat and che st. He was taken to the hospital for examination.

Victim

  1. #1 Hospitalized Age 42 M

    Nature of injury
    21
    Part of body
    28
    Event type
    8
    Source
    19
    Occupation code
    999
    Human factor
    1
    Environmental factor
    7
    Task assigned
    2

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.