Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,991Records 71,450Employers 85,836Hospitalizations 27,959Amputations 2015-01-01 2025-11-30

OSHA Accident Investigation · Summary #14301535

K & S ELECTRIC

Event
ELEC PROTECT EQUIP, OVERHEAD POWER LINE, ELECTRICAL, POWER LINE WORKER, ELECTROCUTED, E PTD, ELEC UTILITY WORK, AERIAL LIFT
NAICS
000000
Inspection type
Accident-driven
Activity number
#104714084
Employer profile
K & S ELECTRIC
Summary number
14301535
Report ID
653510

Event description

ELECTRIC SHOCK - DIRECT CONTACT WITH OVERHEAD LINE

Investigation abstract

A power line worker was working from the bucket of a High Ranger aerial lift mou nted on a Ford truck. The bucket was in a stationary position next to a utility pole. The employee was tightening hardware for an insulator on the pole. To chec k the rear of the mounting bolt, he reached through the middle and upper conduct ors of a 480-volt overhead power line supported on the pole. He touched both con ductors simultaneously and was electrocuted. The medical examiner found a faint burn mark on his left shoulder and another burn mark below his armpit on the lef t side of his chest.

Victim

  1. #1 Fatality Age 26 M

    Nature of injury
    10
    Part of body
    5
    Event type
    13
    Source
    15
    Occupation code
    577
    Human factor
    1
    Environmental factor
    18
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.