Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,991Records 71,450Employers 85,836Hospitalizations 27,959Amputations 2015-01-01 2025-11-30

OSHA Accident Investigation · Summary #14308332

AIRCO DISTRIBUTER GASES DIV. BOC GROUPS INC.

Event
FLAMMABLE VAPORS, WORK RULES, BOILER, EXPLOSION, CHEST, STRUCK BY, FLYING OBJECT
NAICS
000000
Inspection type
Accident-driven
Activity number
#17646738
Employer profile
AIRCO DISTRIBUTER GASES DIV. BOC GROUPS INC.
Summary number
14308332
Report ID
213400

Event description

EMPLOYEE KILLED IN BOILER EXPLOSION

Investigation abstract

THE REFRACTOR LINING OF A BOILER HAD BEEN REPAIRED. TO GAIN ACCESS TO THE BOILER KILLING HIM. THE BOILER WAS MANUFACTURED BY THE H.B. SMITH COMPANY, OF THE 28 SE RIES, MODEL C3-GO-25. THE BURNER UNIT WAS MADE BY POWER FLAME, INC. THE DAY AFTE R ACCIDENT, A TEST OF THE UNIT'S OPERATION WAS CONDUCTED AT THE REQUEST OF THE M IDDLESEX COUNTY PROSECUTORS OFFICE. WITH THE MAIN GAS VALVE CLOSED, THE BURNER W AS STARTED. IT WAS FOUND THAT THE GAS FEED VALVE TO THE BURNER WAS OPENING CONCU RRENTLY WITH THE PURGE. NORMALLY THE FEED VALVE OPENS AFTER A 90 SECOND PURGE AN D DETECTION OF THE PILOT FLAME. AN EXAMINATION OF THE WIRING SHOWED THAT THERE W AS A MISTAKE MADE WHEN THE WIRING WAS RECONNECTED, SUCH THAT THE SAFETY MEASURE (PURGE-FLAME DETECTION) HAD BEEN BYPASSED. PROPER START-UP PROCEDURES WERE NOT F OLLOWED. THE REWIRING JOB SHOULD HAVE BEEN CHECKED AGAINST THE WIRING DIAGRAM. A , THE WIRING FOR THE BURNER CONTROLS HAD BEEN DISCONNECTED AND THE MAIN GAS VALV START-UP CHECK TO CHECK THE SAFETY MEASURE SHOULD HAVE BEEN DONE WITH THE MAIN GAS VALVE CLOSED. E SHUT OFF. AFTER THE REPAIRS WERE COMPLETED THE WIRING WAS RECONNECT BY A MECHA NIC. THE MECHANIC HAD COMPILED AN INCOMPLETE LIST OF THE CONNECTIONS. THE MAIN G AS VALVE WAS THEN OPENED. EMPLOYEE #1 WAS CALLED TO START THE BOILER. HE CLOSED THE BREAKERS, BUT NOTHING HAPPENED. HE CHANGED A FUSE AND ATTEMPTED ANOTHER STAR T-UP. EMPLOYEE #1, ALONG WITH 2 EMPLOYEES OF THE REPAIR COMPANY, WAS STANDING IN FRONT OF BURNER UNIT. AT THE POINT WHEN THE PILOT IS IGNITED, THE UNIT BLEW UP. A COVER PLATE ON THE BURNER UNIT BLEW OFF AND STRUCK EMPLOYEE #1 IN THE CHEST,

Victims (2)

  1. #1 Fatality Age 62 M

    Nature of injury
    18
    Part of body
    5
    Event type
    1
    Source
    6
    Occupation code
    999
    Human factor
    9
    Environmental factor
    5
    Task assigned
    1
  2. #981 Degree 0 Age 0

    Nature of injury
    0
    Part of body
    0
    Event type
    0
    Source
    0
    Occupation code
    0
    Human factor
    0
    Environmental factor
    0
    Task assigned
    0

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.