104,543Records 70,659Employers 84,666Hospitalizations 27,563Amputations 2015-01-01 2025-09-30
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14346175

RECEPTACLE,ELECTRICAL,E C,ELECTRICIAN,ELECTROCUTED,UNGUARDED LIVE PARTS,ELECTRICAL BOX

Event
RECEPTACLE,ELECTRICAL,E C,ELECTRICIAN,ELECTROCUTED,UNGUARDED LIVE PARTS,ELECTRICAL BOX
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14346175
Report ID
420600

Event description

ELECTRIC SHOCK - DIRECT CONTACT WITH EXPOSED LIVE PARTS

Investigation abstract

AN EMPLOYEE WAS IN THE ATTIC OF A RESIDENCE INSTALLING A LIGHTING FIXTURE IN THE CEILING OF A CLOSET. THE EMPLOYEE WAS WORKING NEAR A RECEPTACLE THAT HAD ITS FA CEPLATE REMOVED. THE EMPLOYEE, WHO WAS PERSPIRING, LEANED AGAINST AN AIR CONDITI ONING DUCT WHILE INSTALLING THE WIRING FOR THE FIXTURE. WHEN HE CONTACTED THE LI VE RECEPTACLE, HE WAS ELECTROCUTED.

Victims (2)

  1. #1 Fatality Age 31 M

    Nature of injury
    10
    Part of body
    4
    Event type
    12
    Source
    15
    Occupation code
    575
    Human factor
    9
    Environmental factor
    13
    Task assigned
    1
  2. #981 Degree 0 Age 0

    Nature of injury
    0
    Part of body
    0
    Event type
    0
    Source
    0
    Occupation code
    0
    Human factor
    0
    Environmental factor
    0
    Task assigned
    0