105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14388029

BURN,TANK TRUCK,FLAMMABLE LIQUID,CLEANING,FIRE,DIESEL TRUCK,SPRAYING RIG

Event
BURN,TANK TRUCK,FLAMMABLE LIQUID,CLEANING,FIRE,DIESEL TRUCK,SPRAYING RIG
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14388029
Report ID
524700

Event description

Employee burned in solvent fire

Investigation abstract

Employee #1 was or had been spraying the inside of a semi-tank trailer with Mask Wash, a solvent with a 10 degree F flash point. He was spraying inside the tank with a spray wand on a 40 ft long by 5/16 in. in diameter rubber hose. The hose was supplied from a diesel truck fuel tank containing about 15 to 20 gallons of fuel (130 gallon tank). The tank was pressurized by a shop air line to about 15 psi. A solvent fire occurred and Employee #1 was burned. There was common elect rical wiring throughout, a gas fired caustic tank, a heater, a common extension cord with a trouble light, and a portable iron ladder hung on the rim of the tra iler dome. None was bonded to the trailer.

Victim

  1. #1 Hospitalized Age 36 M

    Nature of injury
    5
    Part of body
    19
    Event type
    14
    Source
    9
    Occupation code
    999
    Human factor
    6
    Environmental factor
    10
    Task assigned
    1