Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,991Records 71,450Employers 85,836Hospitalizations 27,959Amputations 2015-01-01 2025-11-30

OSHA Accident Investigation · Summary #14453765

TONES BROTHERS INC.

Event
AMPUTATED, FINGER, WORK RULES, LOCKOUT, AUGER
NAICS
000000
Inspection type
Accident-driven
Activity number
#101937159
Employer profile
TONES BROTHERS INC.
Summary number
14453765
Report ID
751910

Event description

Employee's finger amputated by filter auger

Investigation abstract

Employee #1 was removing an auger from a line filling funnel. He failed to lock the equipment in place, even though lockout was possible 1 ft away from the funn el. The equipment was run by a computer which sensed that the line run had not f inished. It started up and the auger amputated Employee #1's left index finger.

Victim

  1. #1 Hospitalized Age 28 M

    Nature of injury
    1
    Part of body
    10
    Event type
    2
    Source
    26
    Occupation code
    756
    Human factor
    8
    Environmental factor
    4
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.