105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14478176

AMPUTATED,CLEANING,SLIP,LOCKOUT,TRIPPED,HAND,MEAT BLENDING MACH,UNGUARDED,HOT WATER

Event
AMPUTATED,CLEANING,SLIP,LOCKOUT,TRIPPED,HAND,MEAT BLENDING MACH,UNGUARDED,HOT WATER
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14478176
Report ID
111100

Event description

HAND AMPUTATED IN MEAT BLENDER

Investigation abstract

AT APPROXIMATELY 12:30 AM ON JANUARY 20, 1987, EMPLOYEE #1 WAS CLEANING A MEAT B AND EQUIPMENT COMPANY. POSSIBLE CONTRIBUTING FACTORS ARE: MEAT BY-PRODUCT ON THE FLOOR FROM CLEANING CREATED A SLIPPERY SPOT; THE AUGERS WERE IN OPERATION DURIN G THE CLEANING (THE UNIT COULD BE CLEANED, FOR THE MOST PART, WITHOUT HAVING THE EQUIPMENT IN OPERATION). POSSIBLE ABATEMENT WOULD BE THE ADDITION OF A "JOG" FU NCTION ON THE BLENDER TO ADVANCE IT, AS NEEDED, WITHOUT RUNNING THE UNIT AT FULL SPEED. LENDER, USING A HIGH PRESSURE HOT WATER HOSE. THE AUGERS OF THE BLENDER WERE IN OPERATION AND THE PRODUCT REMOVAL DOORS WERE OPENED FOR CLEANING. THERE WERE NO WITNESSES TO THE ACCIDENT. THE EMPLOYEE PROBABLY SLIPPED OR TRIPPED WHILE CLEANI NG AROUND THE OPEN DOORS. HIS LEFT HAND, WHICH HELD THE HOSE, ENTERED THE BLENDE R AND WAS AMPUTATED BY THE AUGER'S END SCRAPER AS IT SWEPT BY THE SHEER POINT AT THE BLENDER OPENING. THE EMPLOYEE DOES NOT RECALL HOW HIS HAND GOT INTO THE BLE NDER. HE ONLY RECALLS BEING ON THE FLOOR AND THINKING HIS ARM WAS BROKEN. THE BL ENDER WAS A MODEL 125/2, SERIAL NO. M73035, MANUFACTURED BY THE GRIFFITH DESIGN

Victim

  1. #1 Hospitalized Age 21 M

    Nature of injury
    1
    Part of body
    12
    Event type
    2
    Source
    26
    Occupation code
    999
    Human factor
    1
    Environmental factor
    3
    Task assigned
    1