105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14496970

TEMPORARY LIGHTING,ELECTRICAL,INSULATED TOOL,ELECTROCUTED,E C,ELECTRIC CONDUCTOR,HAND TOOL,TEMPORARY WIRING

Event
TEMPORARY LIGHTING,ELECTRICAL,INSULATED TOOL,ELECTROCUTED,E C,ELECTRIC CONDUCTOR,HAND TOOL,TEMPORARY WIRING
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14496970
Report ID
627100

Event description

ELECTRIC SHOCK - CONTACT WITH CONDUCTOR THRU PLIERS

Investigation abstract

AN EMPLOYEE WAS WORKING FROM A 6-FOOT STEPLADDER, ADJUSTING A SPRINKLER PIPE AT AN "ALL-THREAD" HANGER. WIRING FOR SOME TEMPORARY LIGHTING WAS WRAPPED AROUND TH IS HANGER. AS THE EMPLOYEE TWISTED THE HANGER WITH A PAIR OF CHANNEL LOCK PLIERS , THE PLIERS CONTACTED THE INSULATED CONDUCTOR, PIERCING ITS INSULATION. THE EMP LOYEE WAS ELECTROCUTED.

Victim

  1. #1 Fatality Age 41 M

    Nature of injury
    10
    Part of body
    4
    Event type
    6
    Source
    15
    Occupation code
    999
    Human factor
    1
    Environmental factor
    4
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.