105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14500185

ELECTRICAL,E GI VII,FIRE,SMOKE,ELECTRIC CORD,ELECTRICAL FAULT,SMOKE INHALATION

Event
ELECTRICAL,E GI VII,FIRE,SMOKE,ELECTRIC CORD,ELECTRICAL FAULT,SMOKE INHALATION
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14500185
Report ID
523400

Event description

SMOKE INHALATION - ELECTRICAL FAULT IN ELECTRIC CORD

Investigation abstract

Eight employees were at the bottom of a shaft, hooking up a mining machine. Whil e they were doing this, the 575-volt power supply cord on the machine caught fir e, probably due to an electrical fault in the system. Six of the employees exite d the space. The other two employees remained behind to extinguish the fire. The se two employees were eventually rescued and were replaced by fire fighters. The two employees were hospitalized for smoke inhalation.

Victims (2)

  1. #1 Hospitalized Age 55 M

    Nature of injury
    21
    Part of body
    28
    Event type
    8
    Source
    16
    Occupation code
    999
    Human factor
    6
    Environmental factor
    7
    Task assigned
    1
  2. #2 Hospitalized Age 40 M

    Nature of injury
    21
    Part of body
    28
    Event type
    8
    Source
    16
    Occupation code
    999
    Human factor
    6
    Environmental factor
    7
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.