Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,991Records 71,450Employers 85,836Hospitalizations 27,959Amputations 2015-01-01 2025-11-30

OSHA Accident Investigation · Summary #14503627

INSITUFORM MISSOURI, INC.

Event
OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, MANHOLE, E GI IC, METAL PIPE, SCAFFOLD
NAICS
000000
Inspection type
Accident-driven
Activity number
#106026628
Employer profile
INSITUFORM MISSOURI, INC.
Summary number
14503627
Report ID
729700

Event description

ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU METAL PIPE

Investigation abstract

A WORK CREW WAS REPAIRING A SEWER PIPE. THE WERE REMOVING A 4-INCH-DIAMETER FLEX IBLE METAL PIPE FROM A SEWER LINE. THEY WERE PULLING IT OUT OF A MANHOLE, THROUG H THE MANHOLE OPENING. A TUBULAR WELDED FRAME SCAFFOLD HAD BEEN ERECTED ABOVE TH E OPENING, AT A HEIGHT OF 24 FEET, 3 INCHES, AND ADJACENT TO A 7200-VOLT OVERHEA D POWER LINE. ONE OF THE WORKERS WAS STANDING ON THE GROUND, PULLING UP THE SLAC K IN THE PIPE AS IT WAS BEING REMOVED FROM THE MANHOLE. HE WAS ELECTROCUTED WHEN THE PIPE CONTACTED THE OVERHEAD LINE.

Victim

  1. #1 Fatality Age 43 M

    Nature of injury
    10
    Part of body
    4
    Event type
    13
    Source
    15
    Occupation code
    999
    Human factor
    1
    Environmental factor
    8
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.