ELECTRICAL,E GI VII,ELECTROCUTED,GROUND FAULT,ELEC EQUIPMENT--MISC

Event
ELECTRICAL,E GI VII,ELECTROCUTED,GROUND FAULT,ELEC EQUIPMENT--MISC
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14504237
Report ID
728500

Event description

ELECTRIC SHOCK - GROUND FAULT IN WASHING/STEAMING EQUIPMENT

Investigation abstract

AN EMPLOYEE WAS USING A CAR WASHING/STEAMING UNIT TO CLEAN A TRACTOR PART. THE T HREE-PHASE STEAMER PORTION OF THE UNIT WOULD NOT OPERATE BECAUSE ONLY SINGLE-PHA SE POWER WAS AVAILABLE. HOWEVER, THE HEATING ELEMENT FOR THE STEAMER HAD NOT BEE N DISCONNECTED, AND IT SHORTED OUT TO THE MACHINE FRAME. THE WATER PASSING THROU GH THE PRESSURE PUMP CONDUCTED CURRENT TO THE WAND HELD IN THE EMPLOYEE'S HAND. THE EMPLOYEE WAS ELECTROCUTED.

Victim

  1. #1 Fatality Age 46 M

    Nature of injury
    1
    Part of body
    4
    Event type
    12
    Source
    15
    Occupation code
    999
    Human factor
    12
    Environmental factor
    18
    Task assigned
    1