BURN,WORK RULES,INHALATION,HOSE,ANHYDROUS AMMONIA,GAS LEAK,ANKLE,FOOT

Event
BURN,WORK RULES,INHALATION,HOSE,ANHYDROUS AMMONIA,GAS LEAK,ANKLE,FOOT
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14538441
Report ID
452110

Event description

EMPLOYEE EXPOSED TO ANHYDROUS AMMONIA FROM BROKEN HOSE

Investigation abstract

EMPLOYEE #1 WAS PURGING NON-CONDENSABLE GAS FROM AN ANHYDROUS AMMONIA CONDENSER. HE WAS ON THE FIRST RUNG OF A LADDER, OPENING THE PURGE VALVE. A LENGTH OF BOST ON PERFECTION 1000 HIGH PRESSURE AIR AND WATER HOSE WAS BEING USED TO CONNECT TH E PURGE VALVE TO THE PUMP-OUT COMPRESSOR. THE HOSE BURST NEAR EMPLOYEE #1'S FEET . HE SUSTAINED BURNS TO HIS FEET AND ONE ANKLE, AND ALSO HAD SOME INHALATION PRO BLEMS. THE ACCIDENT WAS CAUSED BY THE USE OF A HOSE NOT APPROVED FOR ANHYDROUS A MMONIA. ALSO, THE HOSE WAS NOT IN GOOD CONDITION.

Victim

  1. #1 Hospitalized Age 58 M

    Nature of injury
    4
    Part of body
    11
    Event type
    10
    Source
    9
    Occupation code
    999
    Human factor
    6
    Environmental factor
    15
    Hazardous substance
    0170
    Task assigned
    1