105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #14544969

ELECTRICAL,E GI VII,ELECTROCUTED,GROUND FAULT,EQUIPMENT GROUNDING,ELEC EQUIPMENT--MISC

Event
ELECTRICAL,E GI VII,ELECTROCUTED,GROUND FAULT,EQUIPMENT GROUNDING,ELEC EQUIPMENT--MISC
Linked inspection
No inspection record linked to this accident's victims.
Summary number
14544969
Report ID
418300

Event description

ELECTRIC SHOCK - GROUND FAULT IN ROTO-ROOTER

Investigation abstract

AN EMPLOYEE WAS USING AN ELECTRIC ROTO-ROOTER-TYPE MACHINE TO CLEAN OUT A DRAIN AT A RESIDENCE. THE MACHINE WAS CONNECTED TO ITS SOURCE OF SUPPLY THROUGH AN UNG ROUNDED EXTENSION CORD SET TO A 120-VOLT OUTDOOR LIGHTING FIXTURE. THE MACHINE H AD A GROUND FAULT, WHICH CAUSED THE ELECTROCUTION OF THE EMPLOYEE.

Victim

  1. #1 Fatality Age 20 M

    Nature of injury
    10
    Part of body
    4
    Event type
    13
    Source
    26
    Occupation code
    585
    Human factor
    1
    Environmental factor
    18
    Hazardous substance
    8880
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.