Event description

ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

Investigation abstract

AN ELECTRICIAN AND A COWORKER WERE MOVING A 277-VOLT ELECTRIC POWER LINE ON THE SECOND FLOOR IN THE CENTER OF AN ADMINISTRATION BUILDING. THE ELECTRICIAN TESTED THE CIRCUIT WITH AN IDEAL VOLTAGE TESTER (CATALOG NO. 61-065) AND FOUND THE CIR CUIT TO BE DEENERGIZED. HOWEVER, IN SPITE OF THE TEST, THE CIRCUIT WAS STILL ENE RGIZED. THE ELECTRICIAN WAS ELECTROCUTED WHEN HE CONTACTED AN ENERGIZED CONDUCTO R AND A METAL-CLAD CABLE AT THE SAME TIME. EITHER THE ELECTRICIAN OR HIS COWORKE R OR BOTH WERE UNDER THE INFLUENCE OF DRUGS AT THE TIME OF THE ACCIDENT. (THE RE PORT SIMPLY STATED THAT DRUGS WERE INVOLVED.)