SEWELL PLASTICS INC.

Event
AMPUTATED, MOLDING MACHINE, WORK RULES, CLEANING, CAUGHT BY, INTERLOCK, LOCKOUT, HAND
NAICS
000000
Inspection type
Accident-driven
Activity number
#105434823
Employer profile
SEWELL PLASTICS INC.
Summary number
14568216
Report ID
454510

Event description

EMPLOYEE'S HAND AMPUTATED IN MOLDING MACHINE

Investigation abstract

EMPLOYEE #1 WAS CLEANING A NISSEI STRETCH BLOW MOLDING MACHINE, TYPE A5B6 50 EXI I, SERIAL NUMBER 866 53 56, LOCATED IN THE MOLDING INJECTION DEPARTMENT. THE MAC HINE CYCLED AND CAUGHT EMPLOYEE #1'S RIGHT HAND, PULLING IT INTO THE MACHINE. TH E EMPLOYEE SUFFERED A PARTIAL AMPUTATION OF HIS RIGHT HAND (LEAVING THE THUMB AN D SOME PALM). THE MACHINE DOOR WAS EQUIPPED WITH AN INTERLOCK, BUT IT HAD BEEN B YPASSED WITH A JUMPER WIRE.

Victim

  1. #1 Hospitalized Age 32 M

    Nature of injury
    1
    Part of body
    12
    Event type
    2
    Source
    26
    Occupation code
    755
    Human factor
    9
    Environmental factor
    1
    Hazardous substance
    8880
    Task assigned
    1