Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,991Records 71,450Employers 85,836Hospitalizations 27,959Amputations 2015-01-01 2025-11-30

OSHA Accident Investigation · Summary #221362213

ASTRA ZENECA PHARMACEUTICALS, L.P.

Event
Air Pressure, Amputated, Amputation, Catch Point, Caught In, Closed, Finger, Fingertip, Hand, Instantaneous amputation, Manufacturing, Partial Amputation, Pneumatic, Pneumatic equipment, Pressure Release, Repair, Traumatic Amputation, Valve
NAICS
325412
Inspection type
Referral
Activity number
#345344220
Employer profile
ASTRA ZENECA PHARMACEUTICALS, L.P.
Summary number
221362213
Report ID
0626300

Event description

Employee amputates fingertips when hand is caught in valve

Investigation abstract

At 9:15 a.m. on May 30, 2021, an employee working for a pharmaceutical company was repairing a valve. When the employee released the air from the valve it closed on his left hand. The employee amputated his fingertips and was hospitalized

Victim

  1. #1 Hospitalized Age 59 M

    Event type
    2

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.