OSHA Accident Investigation · Summary #221440597
DYNACAST, LLC
LAKE FOREST, CA·
Event description
Employee punctures, cuts finger when caught in leak test mac
Investigation abstract
At 2:15 a.m. on September 8, 2021, an employee was working as a temporary and the clamp attached to the pneumatic cylinders caught her left index finger. A coworker, who was her supervisor was on the floor, did not witness the accident. The employee received medical treatment without hospitalization for a puncture wound and laceration to the finger. employee at an aluminum components die casting manufacturer. The employee was employed by a staffing agency and was working as a packer at the site. The employee was calibrating a APTIV Model #9242099 Leak Testing Machine prior to testing the actual parts. As a packer, she was assigned to conduct a leak test of each individual component. The leak test machine requires calibration at the beginning of the shift. The employee put the rabbit (testing piece) into the machine and pressed the reset button. She then immediately pressed the cycle start (palm buttons) and the machine cycled. She then reached into the machine
Victim
-
#1 Non-hospitalized injury Age 32 F
- Event type
- 1
- Occupation code
- 758
Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.