OSHA Accident Investigation · Summary #570606
E GI III,ELECTRICAL,ELECTRIC CABLE,ELECTROCUTED,GROUND FAULT,STRAIN RELIEF,ELEC EQUIPMENT--MISC
Event description
ELECTRIC SHOCK - GROUND FAULT IN MUSHROOM SHAKER MACHINE
Investigation abstract
AN EMPLOYEE WAS UNCLOGGING A DRAIN LOCATED UNDER A MUSHROOM SHAKER MACHINE. HE A PPARENTLY LOST HIS BALANCE AND GRABBED THE ELECTRIC SUPPLY CABLE FOR THE MACHINE AS HE FELL. THERE WAS NO STRAIN RELIEF FOR THE CABLE'S CONDUCTORS AT THE MOTOR TERMINAL BOX. THE CABLE PULLED LOOSE, AND ONE CONDUCTOR IN THE CABLE SCRAPED THE BOX, WHICH CUT THROUGH THE INSULATION. THE GROUND FAULT ENERGIZED EITHER THE MA CHINE OR THE CABLE; AND THE EMPLOYEE, WHO WAS STANDING IN WATER, WAS ELECTROCUTE D.