105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #670919

DIE,AMPUTATED,POWER PRESS,FINGER,CLEANING,INTERLOCK,POINT OF OPERATION

Event
DIE,AMPUTATED,POWER PRESS,FINGER,CLEANING,INTERLOCK,POINT OF OPERATION
Linked inspection
No inspection record linked to this accident's victims.
Summary number
670919
Report ID
551800

Event description

EMPLOYEE'S FINGERS AMPUTATED IN POWER PRESS

Investigation abstract

EMPLOYEE #1 WAS REMOVING SCRAPS , BY HAND, FROM THE DIES OF A PRECISION FLEXA PR SPITALIZED. ESS, PART REVOLUTION, 60 TON MECHANICAL POWER PRESS WHEN THE PRESS SUDDENLY ACTI VATED AND THE DIES CLOSED ONTO HER HAND. SHE WAS RELIEVING THE REGULAR OPERATOR AT THIS STATION FOR THE NORMAL BREAK PERIOD. THE PRESS HAS BARRIER GUARDS THAT A RE INTERLOCKED BY MICRO SWITCHES SO THAT WHENEVER THE GUARDS ARE RAISED OR OPENE D THE PRESS SHUTS DOWN. THE FRONT BARRIER GUARD WAS "UP" AT THE TIME OF THE ACCI DENT BUT THE MIRCO SWITCH HAD A "C" TYPE CLIP PLACED ON IT. THE CLIP PREVENTED T HE PRESS FROM SHUTTING OFF WITH THE GUARDS RAISED. THE SECOND, THIRD, AND FOURTH FINGER OF HER RIGHT HAND, AND PART OF HER RIGHT THUMB WAS AMPUTATED. SHE WAS HO

Victim

  1. #1 Hospitalized Age 43 F

    Nature of injury
    1
    Part of body
    12
    Event type
    2
    Source
    26
    Occupation code
    706
    Human factor
    9
    Environmental factor
    2
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.