Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,991Records 71,450Employers 85,836Hospitalizations 27,959Amputations 2015-01-01 2025-11-30

OSHA Accident Investigation · Summary #672063

H-N ADVERTISING & DISPLAY CO INC

Event
DIE, AMPUTATED, BRAKE, PRESS BRAKE, FINGER, MECH MALFUNCTION
NAICS
000000
Inspection type
Accident-driven
Activity number
#104052717
Employer profile
H-N ADVERTISING & DISPLAY CO INC
Summary number
672063
Report ID
551800

Event description

Employee's fingers amputated by press brake

Investigation abstract

At 8:30 a.m. on August 17, 1987, Employee #1 was placing and removing metal part s on a Niagara mechanical press brake, serial #46950. The brake was tripped by a foot pedal and equipped with light curtains. Employee #1 was taking a sheet met al part out of the die when the brake double-tripped and amputated three fingers on her right hand. Employee #1 was hospitalized.

Victim

  1. #1 Hospitalized Age 27 F

    Nature of injury
    1
    Part of body
    10
    Event type
    2
    Source
    26
    Occupation code
    706
    Human factor
    9
    Environmental factor
    1
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.