OSHA Accident Investigation · Summary #707158

PROTECTIVE GROUNDING,E GI IV,ELECTRICAL,ELECTRICAL TESTING,INSULATOR,TEST EQUIPMENT,ELECTRIC SHOCK,UNTRAINED

Event
PROTECTIVE GROUNDING,E GI IV,ELECTRICAL,ELECTRICAL TESTING,INSULATOR,TEST EQUIPMENT,ELECTRIC SHOCK,UNTRAINED
Linked inspection
No inspection record linked to this accident's victims.
Summary number
707158
Report ID
352420

Event description

ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

Investigation abstract

An employee of an insulator manufacturer touched a metal chain hanging from an i nsulator. The chain was used for test purposes after the insulator was deenergiz ed. (The test passed 100 milliamperes through the circuit.) The chain had a resi dual charge on it when the employee contacted it, and he received an electric sh ock.