E GI III,ELECTRICAL,INDUSTRIAL TRUCK,CORD CONNECTOR,ELECTRIC CONDUCTOR,ELECTRIC SHOCK

Event
E GI III,ELECTRICAL,INDUSTRIAL TRUCK,CORD CONNECTOR,ELECTRIC CONDUCTOR,ELECTRIC SHOCK
Linked inspection
No inspection record linked to this accident's victims.
Summary number
707778
Report ID
352420

Event description

ELECTRIC SHOCK - CONTACT WITH ENERGIZED PARTS

Investigation abstract

AN EMPLOYEE WAS CHANGING THE ELECTRIC HOIST ON A WIRE DRAWING BLOCK. HE WAS STAN DING IN A WORK CAGE ON A FORKLIFT HOLDING A CORD CONNECTOR IN HIS HAND SO THAT H E COULD CONNECT THE NEW HOIST. (A COWORKER WAS IN THE WORK CAGE WITH HIM.) THE C LARK FORKLIFT DROPPED A FEW INCHES, CAUSING THE EMPLOYEE TO LOSE HIS BALANCE. TH E CONDUCTORS IN THE CONNECTOR WERE TORN FROM THEIR TERMINALS, AND THE EMPLOYEE R ECEIVED AN ELECTRIC SHOCK WHEN HE CONTACTED ENERGIZED PARTS. THE EMPLOYEE WAS NO T HOSPITALIZED FOR HIS INJURIES.

Victim

  1. #1 Non-hospitalized injury Age 45 M

    Nature of injury
    10
    Part of body
    12
    Event type
    13
    Source
    15
    Occupation code
    544
    Human factor
    12
    Environmental factor
    6
    Task assigned
    1