105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #827121

DIE,AMPUTATED,POWER PRESS,FINGER,WORK RULES,POINT OF OPERATION,SET UP,UNTRAINED,COMMUNICATION

Event
DIE,AMPUTATED,POWER PRESS,FINGER,WORK RULES,POINT OF OPERATION,SET UP,UNTRAINED,COMMUNICATION
Linked inspection
No inspection record linked to this accident's victims.
Summary number
827121
Report ID
751910

Event description

Employee's finger amputated by power press die

Investigation abstract

Employee #1 was operating a 100 ton Bliss power press. She released the palm but re putting parts or their hands into the die area. The press had all the safegua rding required by IOSHA standards. tons before the press completed its stroke. The press then had to be jogged back to the top of the stroke to reset it. When the set-up person reset the press, s he inadvertently set the control knob to continuous stroke rather than single st roke. When Employee #1 started to run the press again, she put a part into the p ress and tripped the palm buttons. When she reached into the die to remove the p art, the press tripped again and continued to run, catching her fingers in the d ie. Her fingers were amputated. The accident was caused by human error and lack of operator training. Employees were not trained to check the press cycling befo

Victim

  1. #1 Non-hospitalized injury Age 21 F

    Nature of injury
    1
    Part of body
    10
    Event type
    2
    Source
    26
    Occupation code
    706
    Human factor
    4
    Environmental factor
    1
    Task assigned