Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,991Records 71,450Employers 85,836Hospitalizations 27,959Amputations 2015-01-01 2025-11-30

OSHA Accident Investigation · Summary #889436

MNDL CORPORATION

Event
OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, METAL PIPE, E GI IB
NAICS
000000
Inspection type
Accident-driven
Activity number
#104390950
Employer profile
MNDL CORPORATION
Summary number
889436
Report ID
352430

Event description

ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU METAL TOWER

Investigation abstract

Two employees were assembling 9.1-meter-tall towers in the parking lot of a groc employees heard someone shout "Watch out! Electric lines!" just before the conta ct. He let go of the tower before it contacted the power line. The other employe e apparently did not let go and was electrocuted. ery store. The towers were going to be used to simulate rain in the filming of a motion picture. They were constructed primarily of 76-millimeter-diameter alumi num pipe. One piece extended upward supported by braces to form a tripod on whee ls. Each tower had hose connections and valves to carry water to the top. The tw o employees were told to move the towers from the parking lot to an area near wh ere they were to be used. As they rolled the towers across the parking lot, thro ugh the gate, and onto the driveway pad, a distance of about 15 meters, the towe r leaned toward the street and contacted an overhead power line. One of the two

Victim

  1. #1 Fatality Age 44 M

    Nature of injury
    10
    Part of body
    29
    Event type
    13
    Source
    15
    Occupation code
    873
    Human factor
    1
    Environmental factor
    8
    Task assigned
    2