105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #976845

MAINTENANCE,AMPUTATED,POWER PRESS,FINGER,WORK RULES,POINT OF OPERATION,FOOT-POWERED PRESS,UNGUARDED,INATTENTION

Event
MAINTENANCE,AMPUTATED,POWER PRESS,FINGER,WORK RULES,POINT OF OPERATION,FOOT-POWERED PRESS,UNGUARDED,INATTENTION
Linked inspection
No inspection record linked to this accident's victims.
Summary number
976845
Report ID
551800

Event description

Employee's finger amputated in power press

Investigation abstract

At approximately 8:00 p.m. on December 9, 1988, Employee #1 was operating a Land j 60 ton full-revolution mechanical power press, serial #56481A, that had two re cessed hand palm buttons. Employee #1 turned the key selector to foot pedal and began operating the press without point of operation guarding. When Employee #1 reached with his right hand into the point of operation to remove a slug he acci dentally tripped the press and his right middle finger was amputated to the seco nd knuckle. Employee #1 was taken to St. Joseph Hospital in Kokomo, IN, and late r was taken to St. Vincent's Hospital in Indianapolis, IN.

Victim

  1. #1 Hospitalized Age 49 M

    Nature of injury
    1
    Part of body
    10
    Event type
    2
    Source
    26
    Occupation code
    706
    Human factor
    9
    Environmental factor
    1
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.