OSHA Accident Investigation · Summary #978494
E GI V,ELECTRICAL,CORD SET,ELECTROCUTED,ATTACHMENT PLUG,GROUND FAULT,EQUIPMENT GROUNDING
Event description
ELECTRIC SHOCK - GROUND FAULT IN CORD SET
Investigation abstract
AN EMPLOYEE WAS INSTALLING METAL FASCIA PANELS ON THE FRONT OF A SINGLE STORY BU ILDING. AN EXTENSION CORD SET BEING USED ON THE JOBSITE HAD A GROUND FAULT (THE UNGROUNDED CONDUCTOR WAS CONTACTING THE EQUIPMENT GROUNDING CONDUCTOR). ADDITION ALLY, THE GROUNDING BLADE FOR THE ATTACHMENT PLUG ON THE CORD SET HAD BEEN REMOV ED. THE EMPLOYEE WAS ELECTROCUTED WHEN HE PICKED UP AN ATTACHMENT PLUG WITH A ME TAL HOUSING. THE HOUSING WAS ENERGIZED BY THE GROUND FAULT AND LACK OF PROPER GR OUNDING IN THE EXTENSION CORD SET.
Victim
-
#1 Fatality Age 39 M
- Nature of injury
- 10
- Part of body
- 31
- Event type
- 13
- Source
- 15
- Occupation code
- 999
- Human factor
- 9
- Environmental factor
- 18
- Task assigned
- 1
Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.