105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Accident Investigation · Summary #978502

DIE,INADEQUATE MAINT,PRESS BRAKE,WORK RULES,FOOT CONTROL,POINT OF OPERATION,STRUCK BY,PRESS OPERATOR,HAND,UNGUARDED

Event
DIE,INADEQUATE MAINT,PRESS BRAKE,WORK RULES,FOOT CONTROL,POINT OF OPERATION,STRUCK BY,PRESS OPERATOR,HAND,UNGUARDED
Linked inspection
No inspection record linked to this accident's victims.
Summary number
978502
Report ID
454712

Event description

Employee's hand amputated in press brake

Investigation abstract

Employee #1 was operating a Verson press brake on which the light curtain had tw o light cells inoperative, leaving a 3 1/2 in. gap. She apparently stepped on th e foot switch and the press brake cycled, catching her hand between the dies. Sh e was hospitalized for an amputation.

Victim

  1. #1 Hospitalized Age 21 F

    Nature of injury
    1
    Part of body
    10
    Event type
    2
    Source
    26
    Occupation code
    999
    Human factor
    9
    Environmental factor
    4
    Task assigned
    1

Codes shown verbatim from OSHA's accident-investigation database. A human-readable decoder is coming in a future release once the accident_lookup2 dictionary is loaded.