Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,991Records 70,589Employers 85,836Hospitalizations 27,959Amputations 2015-01-01 2025-11-30

PacTiv LLC

Struck against stationary object or equipment, n.e.c. · Amputations

Federal OSHA recorded a severe workplace injury at PacTiv LLC, 3000 Pegasus Drive, TEMPLE, TEXAS 76501 on , Amputations, affecting the finger(s), fingernail(s), unspecified.

Watch PacTiv LLC for free Get an email when a new federal OSHA severe-injury report for PacTiv LLC is published. One employer, no account, unsubscribe in one click.

An employee was on the air ring of an extruder drum, trying to pull up a foam sheet that was being fed from a lower platform but had jammed against a slitter blade. The employee's left index finger contacted the stationary slitter blade, and the pad was cut off.

Amputation Finger(s), fingernail(s), unspecified Extruding machinery

View PacTiv LLC's full OSHA safety record →