Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,991Records 70,589Employers 85,836Hospitalizations 27,959Amputations 2015-01-01 2025-11-30

Peco Foods, Inc

Caught in or compressed by equipment or objects, unspecified · Amputations

Federal OSHA recorded a severe workplace injury at Peco Foods, Inc, 4114 US 67 South, POCAHONTAS, ARKANSAS 72455 on , Amputations, affecting the fingertip(s).

Watch Peco Foods, Inc for free Get an email when a new federal OSHA severe-injury report for Peco Foods, Inc is published. One employer, no account, unsubscribe in one click.

At approximately 8:30 AM, a maintenance team was troubleshooting a metal detector that was continuously rejecting product. The directional air valve and piping had been disassembled during sanitation and were not re-installed correctly. Maintenance team members disassembled a 3-foot section of piping to visually identify the issue. The injured employee was removing some product from the pipe when the directional air valve actuated. The employee's left little finger was pinched by the valve, amputating the fingertip.

Amputation Fingertip(s) Food and beverage processing machinery-specialized, n.e.c.

View Peco Foods, Inc's full OSHA safety record →