Struck by running powered equipment during maintenance, cleaning, testing · Amputations, avulsions, enucleations unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Meteor Sealing Systems, LLC, 400 S. Tuscarawas Avenue, DOVER, OHIO 44622
on , Amputations, avulsions, enucleations unspecified, affecting the thumb(s).
Watch Meteor Sealing Systems, LLC for freeGet an email when a new federal OSHA severe-injury report for Meteor Sealing Systems, LLC is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was clearing jammed material from an extruder machine. The employee reached their left hand through the unguarded opening between the extruder machine and the conveyor belt to manually dislodge the jam and contacted the moving chain and sprockets, resulting in an amputation to the left thumb.