2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Greer Springs

Injury · Days away from work

On , an injury at Greer Springs in Greer, SC 29651 resulted in days away from work. Employee was coiler in spring Manufacturer.

Establishment
Greer Springs
Parent company
MW Components
Street
2375 SC-101
City
Greer
State
SC
ZIP
29651
On-site location
Coiling
Outcome
Days away from work (code 2)
Type
Injury (code 1)
Days away from work
1
Days restricted or transferred
7

Coiling a Spring

Employee punctured his ring and pinky finger when the mandrel on the machine returned on the coiler

Puncture to right pinky and ring fiinger

the Mandrel on the coiling machine

Employee was coiling a spring when the mandrel on the coiling machine returned and punctured the employees right pinky and ring finger

Job description
Coiler
SOC code
9999 — Uncoded
NAICS code
332613 — Spring Manufacturer
NAICS vintage
2022
Avg employees
120
Total hours worked
213951
EIN
382938499
Establishment ID
1304196
Employer case #
2024-0067
Date of incident
Shift started
15:00
Time of incident
19:40
Filing year
2024
Submitted
12FEB2025:13:28:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year 2024. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.