Evansville, IN ·
OSHA Injury Report: SRG Global, INC
Other illness · Other recordable case
At a glance
On , an other illness at SRG Global, INC in 601 N Congress Ave, Evansville, IN 47715 resulted in other recordable case. Employee was mold Start Up Technician in anodizing metals and metal products for the trade.
Where did this happen?
- Establishment
- SRG Global, INC
- Parent company
- Guardian Automotive
- Street
- 601 N Congress Ave
- City
- Evansville
- State
- IN
- ZIP
- 47715
- On-site location
- Press 1
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Other illness (code 6)
Before the incident
Cleaning mold in press 1
What happened
Employee received burns on his left hand due to contact with hot plastic from press 1.
Injury or illness
second degree burn
Object or substance involved
hot plastic
Summary line
Tech was cleaning degraded plastic off the mold in press 1. The barrel was still forward causing the plastic to be under pressure. It popped and sprayed his left hand with hot plastic.
Employee and industry
- Job description
- Mold Start Up Technician
- SOC code
- 9999: Uncoded
- NAICS code
- 332813: Anodizing metals and metal products for the trade
- NAICS vintage
- 2012
- Employees at this establishment (2024 average)
- 310
- Hours worked at this establishment (2024 total)
- 852,064
- Establishment ID
- 1006805
- Employer case #
- 53429
When (timing detail)
- Date of incident
- Shift started
- 06:00
- Time of incident
- 09:30
- Filing year
- 2024
- Submitted to OSHA
- 2025-02-19
More injuries at SRG Global, INC
View SRG Global, INC's full OSHA safety record →
More injuries in this industry (NAICS 332813)
More injuries in IN
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year 2024. ITA Case Detail records are establishment-reported submissions, not OSHA inspections, so no per-record IMIS deep link exists.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.