Bremen, IN —
OSHA Injury Report: Bremen Wire Plant
Injury · Other recordable case
At a glance
On , an injury at Bremen Wire Plant in Bremen, IN 46506 resulted in other recordable case. Employee was operator Packaging in copper rolling drawing extruding and alloying..
Where did this happen?
- Establishment
- Bremen Wire Plant
- Parent company
- Southwire
- Street
- 515 Copperfield Way
- City
- Bremen
- State
- IN
- ZIP
- 46506
- On-site location
- Accumulator for MGS takeup on EJ11
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Handling wire
What happened
Wire broke so line went down and some wire came off the accumulator sheaves. Since the line was down the take-up operator opened the door to the accumulator to place wire back on the sheaves. TM entered the enclosure and was wrapping the wire. The had their left hand on top of the sheaves and were looking down and to the right when the accumulator started to rise. Their left hand was caught under the last wrap of wire and they jerked their hand free. TM was treated with RICE and ART and after 8 weeks requested medical treatment. They were diagnosed with a partially healed fracture to the distal phalange.
Injury or illness
Fracture; Finger - Ring Left
Object or substance involved
Caught between the wire and moving equipment
Summary line
Fracture to the distal phalange from caught between wire
Employee and industry
- Job description
- Operator Packaging
- SOC code
- 9999 — Uncoded
- NAICS code
- 331420 — Copper rolling drawing extruding and alloying.
- NAICS vintage
- 2012
- Avg employees
- 625
- Total hours worked
- 1404296
- EIN
- 582020515
- Establishment ID
- 619079
- Employer case #
- USBREMEN24
When (timing detail)
- Date of incident
- Shift started
- 5:00
- Time of incident
- 16:00
- Filing year
- 2024
- Submitted
- 28FEB2025:19:22:00
Source