HUNTINGTON, IN —
OSHA Injury Report: DFA FLUID - HUNTINGTON IN
Injury · Other recordable case
At a glance
On , an injury at DFA FLUID - HUNTINGTON IN in HUNTINGTON, IN 46750 resulted in other recordable case. Employee was cIP Operator in fLUID MILK MANUFACTURING.
Where did this happen?
- Establishment
- DFA FLUID - HUNTINGTON IN
- Parent company
- DFA DAIRY BRANDS FLUID LLC
- Street
- 1019 FLAXMILL ROAD
- City
- HUNTINGTON
- State
- IN
- ZIP
- 46750
- On-site location
- Right outside the filler room at the COP tanks
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Filling out charts for CIP.
What happened
[REDACTED] went to shut of the air to the steam line. The shut offs weren 't working for the shut off 's that were on the air line. After the water was up to temp while [REDACTED] was trying to get the shut off valve closed water splashed out of the COP tank onto his left calf and left a burn. He did not realize how bad it was until he went to change at the end of his shift.
Injury or illness
Burn on the left calf.
Object or substance involved
Hot water out of the COP tank.
Summary line
Hot water splashed out of the COP tank onto his left leg causing slight burn on left calf.
Employee and industry
- Job description
- CIP Operator
- SOC code
- 9999 — Uncoded
- NAICS code
- 311511 — FLUID MILK MANUFACTURING
- NAICS vintage
- 2012
- Avg employees
- 461
- Total hours worked
- 404874
- EIN
- 850489560
- Establishment ID
- 709568
- Employer case #
- 2024-028
When (timing detail)
- Date of incident
- Shift started
- 21:30
- Time of incident
- 22:00
- Filing year
- 2024
- Submitted
- 05MAR2025:04:58:00
Source