2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Actylis Eugene - Polk

Injury · Other recordable case

On , an injury at Actylis Eugene - Polk in Eugene, OR 97402 resulted in other recordable case. Employee was chemist II in biotechnology research and development laboratories or services in the medical sciences (except nanobiotechnology research and development).

Establishment
Actylis Eugene - Polk
Parent company
Actylis
Street
90 N. Polk St
City
Eugene
State
OR
ZIP
97402
On-site location
OCN Lab
Outcome
Other recordable case (code 4)
Type
Injury (code 1)

Adjusting fittings on a diaphragm pump

While tightening a fitting using two wrenches a wrench slipped off resulting in a jerk of the tubing. The transfer pump had previously been rinsed with ethanol methanol and contained residual solvent. When the tubing jerked a quantity of solution was flicked below employee 's safety glasses and splashed onto their eye.

Injury to eye

Methanol Ethanol Solution

Chemical Exposure to eye

Job description
Chemist II
SOC code
19-2031 — Chemists
NAICS code
541714 — Biotechnology research and development laboratories or services in the medical sciences (except nanobiotechnology research and development)
NAICS vintage
2022
Avg employees
24
Total hours worked
40768
EIN
930774465
Establishment ID
1401845
Employer case #
N-2025020
Date of incident
Shift started
8:00
Time of incident
9:45
Filing year
2025
Submitted
14JAN26:19:45:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year 2025. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.