2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Prysmian Cables and Systems USA, LLC Marshall

Injury · Days away from work

On , an injury at Prysmian Cables and Systems USA, LLC Marshall in Scottsville, TX 75688 resulted in days away from work. Employee was oPR EXTRUDER in wire and Cable Manufacturing.

Establishment
Prysmian Cables and Systems USA, LLC Marshall
Street
P.O. Box 430 9975 US Highway 80 East
City
Scottsville
State
TX
ZIP
75688
On-site location
54 Line metering capstan
Outcome
Days away from work (code 2)
Type
Injury (code 1)
Days away from work
7
Days restricted or transferred
92

Looking for the cause of loose serve wires

TM found what was causing the loose serve wires and lifted the door that protects the associate from the belts of the capstan.

Right tip of the thumb amputation

Cable and the belt

AMPUTATION Upper Extremities-Thumb Right Side FAILURE TO FOLLOW PROCEDURES [REDACTED]

Job description
OPR EXTRUDER
SOC code
9999 — Uncoded
NAICS code
331420 — Wire and Cable Manufacturing
NAICS vintage
2022
Avg employees
512
Total hours worked
1136823
EIN
571061511
Establishment ID
931103
Employer case #
2023-101
Date of incident
Submitted
06FEB24:17:22:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.