Scottsville, TX —
OSHA Injury Report: Prysmian Cables and Systems USA, LLC Marshall
Injury · Other recordable case
At a glance
On , an injury at Prysmian Cables and Systems USA, LLC Marshall in Scottsville, TX 75688 resulted in other recordable case. Employee was oPR TUBULAR STRANDER DEGLAR in wire and Cable Manufacturing.
Where did this happen?
- Establishment
- Prysmian Cables and Systems USA, LLC Marshall
- Street
- P.O. Box 430 9975 US Highway 80 East
- City
- Scottsville
- State
- TX
- ZIP
- 75688
- On-site location
- 13 latching station
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Getting spools off pallet
What happened
Spool was not sitting on the pallet correctly. leaned up against another spool
Injury or illness
Left pinky finger
Object or substance involved
Spools
Summary line
LACERATION Upper Extremities-Finger(s) Left Side FAILURE TO FOLLOW PROCEDURES spool
Employee and industry
- Job description
- OPR TUBULAR STRANDER DEGLAR
- SOC code
- 9999 — Uncoded
- NAICS code
- 331420 — Wire and Cable Manufacturing
- NAICS vintage
- 2022
- Avg employees
- 512
- Total hours worked
- 1136823
- EIN
- 571061511
- Establishment ID
- 931103
- Employer case #
- 2023-126
When (timing detail)
- Date of incident
- Submitted
- 06FEB24:17:22:00
Source