Jacksonville, FL —
OSHA Injury Report: BAE Systems Maritime Solutions Jacksonville
Injury · Days away from work
At a glance
On , an injury at BAE Systems Maritime Solutions Jacksonville in Jacksonville, FL 32226 resulted in days away from work. Employee was leadperson in ship repair done in a shipyard.
Where did this happen?
- Establishment
- BAE Systems Maritime Solutions Jacksonville
- Parent company
- BAE Systems, Inc.
- Street
- 8500 Heckscher Dr
- City
- Jacksonville
- State
- FL
- ZIP
- 32226
- On-site location
- JSR; USS Ramage; Crew Berthing #6
What was the outcome?
- Outcome
- Days away from work (code 2)
- Type
- Injury (code 1)
- Days away from work
- 65
- Days restricted or transferred
- 115
Before the incident
Stepping on a bunker
What happened
JSR Pipe Shop Employee was conducting fire main light off in [REDACTED] # [REDACTED] onboard [REDACTED] ([REDACTED]). JSR Pipe Shop stood on a sturdy pipe in the space in efforts to ensure that the fire main valve was in the opened position. While reaching for the valve JSR Pipe Shop Employee slipped lost his footing and his left hand got lodged in between a fire main valve and a chill water valve as he attempted to break his fall.
Injury or illness
Sprain left hand
Object or substance involved
Catching himself during a slip
Summary line
Sprain left hand
Employee and industry
- Job description
- Leadperson
- SOC code
- 00-9900 — Insufficient Information - NIOSH
- NAICS code
- 336611 — Ship repair done in a shipyard
- NAICS vintage
- 2022
- Avg employees
- 809
- Total hours worked
- 1726615
- Establishment ID
- 1434778
- Employer case #
- 52698
When (timing detail)
- Date of incident
- Shift started
- 6:30
- Time of incident
- 13:00
- Filing year
- 2025
- Submitted
- 23JAN26:11:45:00
Source