Claremore, OK —
OSHA Injury Report: AXH Air-Coolers
Injury · Other recordable case
At a glance
On , an injury at AXH Air-Coolers in Claremore, OK 74017 resulted in other recordable case. Employee was aSSEMBLER in boilers, power, manufacturing.
Where did this happen?
- Establishment
- AXH Air-Coolers
- Parent company
- AXH Air-Coolers
- Street
- 401 E Lowry Road
- City
- Claremore
- State
- OK
- ZIP
- 74017
- On-site location
- ASSEMBLY
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
Torqueing a paraflex on an F Type cooler.
What happened
Employee was standing on the fan ring tightening the bolts on a PX. The socket slipped off the bolt he was tightening and caused him to lose his balance fell into the fan ring hole sheet metal edge
Injury or illness
Left elbow laceration
Object or substance involved
sheet metal edge
Summary line
Laceration of left elbow from sheet metal edge.
Employee and industry
- Job description
- ASSEMBLER
- SOC code
- 51-2099 — Assemblers and Fabricators, All Other
- NAICS code
- 332410 — Boilers, power, manufacturing
- NAICS vintage
- 2012
- Avg employees
- 776
- Total hours worked
- 1926682
- EIN
- 830414744
- Establishment ID
- 1044944
- Employer case #
- AXH008
When (timing detail)
- Date of incident
- Shift started
- 6:00
- Time of incident
- 8:00
- Filing year
- 2025
- Submitted
- 04FEB26:16:00:00
Source