2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: American Wire and Cable Co

Injury · Days away from work

On , an injury at American Wire and Cable Co in Olmsted Twp, OH 44138 resulted in days away from work. Employee was rewind extrusion in insulated wire or cable, copper, made in integrated secondary smelting and wire drawing plants.

Establishment
American Wire and Cable Co
Parent company
American Wire and Cable Co
Street
7951 Bronson Rd
City
Olmsted Twp
State
OH
ZIP
44138
On-site location
Extrusion plant rewind area
Outcome
Days away from work (code 2)
Type
Injury (code 1)
Days away from work
3

Employee was moving a drum of wire.

Worker was dumping a drum and felt a pop in her rt wrist

Rt wrist strain rt wrist sprain

Drum of wire

Moving a drum and felt a pop in Rt wrist

Job description
Rewind extrusion
SOC code
51-4021 — Extruding and Drawing Machine Setters, Operators, and Tenders, Metal and Plastic
NAICS code
331420 — Insulated wire or cable, copper, made in integrated secondary smelting and wire drawing plants
NAICS vintage
2022
Avg employees
65
Total hours worked
151673
EIN
341080735
Establishment ID
308783
Employer case #
2
Date of incident
Shift started
3:30:00.000
Time of incident
12:30:00.000
Submitted
08FEB24:19:26:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.