Hermitage, PA —
OSHA Injury Report: CCL Container
Hearing loss · Other recordable case
At a glance
On , a hearing loss at CCL Container in Hermitage, PA 16148 resulted in other recordable case. Employee was qA Technician in aerosol cans, light gauge metal, manufacturing.
Where did this happen?
- Establishment
- CCL Container
- Parent company
- CCL Industries
- Street
- 1 LLodio Drive
- City
- Hermitage
- State
- PA
- ZIP
- 16148
- On-site location
- CCL Container
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Hearing loss (code 5)
Before the incident
Annual hearing test
What happened
Annual hearing test resulted in STS & 25 dB or more in left ear
Injury or illness
Annual hearing test resulted in STS & 25 dB or more in left ear
Object or substance involved
STS & 25 dB or more in left ear
Summary line
Annual hearing test resulted in STS & 25 dB or more in left ear
Employee and industry
- Job description
- QA Technician
- SOC code
- 51-9061 — Inspectors, Testers, Sorters, Samplers, and Weighers
- NAICS code
- 332431 — Aerosol cans, light gauge metal, manufacturing
- NAICS vintage
- 2022
- Avg employees
- 287
- Total hours worked
- 638594
- Establishment ID
- 837185
- Employer case #
- 11
When (timing detail)
- Date of incident
- Submitted
- 12JAN24:14:01:00
Source