Plymouth, MN ·
OSHA Injury Report: Medtronic - Nathan Lane
Injury · Other recordable case
At a glance
On , an injury at Medtronic - Nathan Lane in 4600 Nathan Lane, Plymouth, MN 55442 resulted in other recordable case. Employee was assembler in catheters manufacturing.
Where did this happen?
- Establishment
- Medtronic - Nathan Lane
- Parent company
- Medtronic Inc.
- Street
- 4600 Nathan Lane
- City
- Plymouth
- State
- MN
- ZIP
- 55442
- On-site location
- Clean Room 2 - Silicone Room
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
performing normal task - spraying Liquid nitrogen onto part for shape-setting
What happened
Liquid Nitrogen canister was inverted tilted causing the pressure relief valve to release liquid nitrogen and sprayed under safety glasses into eyes
Injury or illness
Chemical Exposure to eye Eye irritation
Object or substance involved
Chemical - Liquid Nitrogen
Summary line
Eye irritation from liquid nitrogen
Employee and industry
- Job description
- Assembler
- SOC code
- 51-2099: Assemblers and Fabricators, All Other
- NAICS code
- 339112: Catheters manufacturing
- NAICS vintage
- 2012
- Employees at this establishment (2025 average)
- 949
- Hours worked at this establishment (2025 total)
- 1,822,762
- EIN
- 510947787
- Establishment ID
- 898965
- Employer case #
- 6576
When (timing detail)
- Date of incident
- Shift started
- 06:00
- Time of incident
- 14:02
- Filing year
- 2025
- Submitted to OSHA
- 2026-03-02
More injuries at Medtronic - Nathan Lane
View Medtronic - Nathan Lane's full OSHA safety record →
More injuries in this industry (NAICS 339112)
More injuries in MN
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year 2025. ITA Case Detail records are establishment-reported submissions, not OSHA inspections, so no per-record IMIS deep link exists.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.