Wausau, WI —
OSHA Injury Report: Waussau East - D142
Injury · Job transfer or restriction
At a glance
On , an injury at Waussau East - D142 in Wausau, WI 54401 resulted in job transfer or restriction. Employee was production and Maintenance II in manufacture of Metal Cans.
Where did this happen?
- Establishment
- Waussau East - D142
- Parent company
- Sonoco
- Street
- 833 South 60th Ave
- City
- Wausau
- State
- WI
- ZIP
- 54401
- On-site location
- Rychiger 283
What was the outcome?
- Outcome
- Job transfer or restriction (code 3)
- Type
- Injury (code 1)
- Days restricted or transferred
- 10
Before the incident
Adjusting sealing pressure to lane 1 on [REDACTED] to improve on footprint quality
What happened
EE struck left hand with rubber mallet while holding spanner wrench to loosen lock collar for upper sealing. Laceration occurred between the thumb and forefinger which started bleeding immediately. First aid was applied then the decision was to go to the ER. Wound was closed with steri-strips and EE was given a tetanus shot and prescription antibiotic.
Injury or illness
laceration - left hand
Object or substance involved
plastic mallet
Summary line
EE struck left hand with rubber mallet while holding spanner wrench to loosen lock collar for upper sealing. Laceration occurred between the thumb and forefinger which started bleeding immediately. First aid was applied then the decision was to go to
Employee and industry
- Job description
- Production and Maintenance II
- SOC code
- 49-9041 — Industrial Machinery Mechanics
- NAICS code
- 332431 — Manufacture of Metal Cans
- NAICS vintage
- 2022
- Avg employees
- 55
- Total hours worked
- 110037
- EIN
- 570248420
- Establishment ID
- 1528149
- Employer case #
- WAU004
When (timing detail)
- Date of incident
- Shift started
- 23:00
- Time of incident
- 23:46
- Filing year
- 2025
- Submitted
- 03MAR26:18:19:00
Source