Eugene, OR —
OSHA Injury Report: sublime solutions llc
Hearing loss · Other recordable case
At a glance
On , a hearing loss at sublime solutions llc in Eugene, OR 97402 resulted in other recordable case. Employee was production Technician in flavoring concentrates (except coffee based) manufacturing.
Where did this happen?
- Establishment
- sublime solutions llc
- Parent company
- sublime solutions llc
- Street
- 500 South Danebo Avenue
- City
- Eugene
- State
- OR
- ZIP
- 97402
- On-site location
- Extraction Room
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Hearing loss (code 5)
Before the incident
Recovering isobutane from the current column.
What happened
A brass high-pressure tri-clamp nut failed at the end of an extraction run causing an explosive decompression.
Injury or illness
Ruptured Eardrum
Object or substance involved
Concussive shockwave.
Summary line
Concussion wave to right ear from explosive decompression resulting in Ruptured Eardrum.
Employee and industry
- Job description
- Production Technician
- SOC code
- 51-9111 — Packaging and Filling Machine Operators and Tenders
- NAICS code
- 311930 — Flavoring concentrates (except coffee based) manufacturing
- NAICS vintage
- 2012
- Avg employees
- 24
- Total hours worked
- 46505
- EIN
- 472305730
- Establishment ID
- 922472
- Employer case #
- 1
When (timing detail)
- Date of incident
- Shift started
- 6:30
- Time of incident
- 8:00
- Filing year
- 2025
- Submitted
- 05MAR26:22:38:00
Source