2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Direct Coil USA, Inc

Injury · Other recordable case

On , an injury at Direct Coil USA, Inc in Fayetteville, TN 373E6 resulted in other recordable case. Employee was dIRECT LABOUR in air-conditioning and warm air heating combination units manufacturing.

Establishment
Direct Coil USA, Inc
Parent company
Direct Coil USA, Inc
Street
1810 Wilson Parkway, Suite A
City
Fayetteville
State
TN
ZIP
373E6
On-site location
1810 Wilson Pkwy Fayetteville Tn 37334
Outcome
Other recordable case (code 4)
Type
Injury (code 1)

He had feel asleep for several hours in his truck after his lunch period. He was awakened by his supervisor and came back in to work and was expanding coils.

Expander gun was not adjusted properly by the employee in which he was trained. Pressure escaped from gun and contacted his had that was misplaced on the gun.

Pressure puncture to the right hand.

Expander fluid

At approximately [REDACTED] [REDACTED] (supervisor) heard employee yell out in pain. [REDACTED] immediately went to the employee at which time [REDACTED] said his finger was pinched in the expander gun. At this time the employee was taken to the hospital.

Job description
DIRECT LABOUR
SOC code
9999 — Uncoded
NAICS code
333415 — Air-conditioning and warm air heating combination units manufacturing
NAICS vintage
2022
Avg employees
68
Total hours worked
120297
EIN
851304187
Establishment ID
1137959
Employer case #
202300002
Date of incident
Shift started
22:30:00.000
Time of incident
6:13:00.000
Submitted
19FEB24:21:26:00