2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Kenyon Plastering of Southern CA, Inc.--San Marcos Div

Injury · Days away from work

On , an injury at Kenyon Plastering of Southern CA, Inc.--San Marcos Div in San Marcos, CA 92078 resulted in days away from work. Employee was scaffold in stucco contractors.

Establishment
Kenyon Plastering of Southern CA, Inc.--San Marcos Div
Parent company
Kenyon Plastering of Southern CA, Inc.
Street
1410 La Mirada Dr.
City
San Marcos
State
CA
ZIP
92078
On-site location
jobsite
Outcome
Days away from work (code 2)
Type
Injury (code 1)
Days away from work
82

receiving material for scaffold

while recieving scaffold material he touched a powerline that PGE did not shut power off for

severe burns

unknown if it was arflash or scaffold touching powerline still under investigation

electrocution due to cut powerline

Job description
scaffold
SOC code
47-2021 — Brickmasons and Blockmasons
NAICS code
238140 — Stucco contractors
NAICS vintage
2022
Avg employees
193
Total hours worked
371052
EIN
364762999
Establishment ID
299922
Employer case #
12
Date of incident
Shift started
6:00:00.000
Time of incident
9:40:00.000
Submitted
21FEB24:22:46:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.