2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: Datwyler Sealing Solutions

Injury · Other recordable case

On , an injury at Datwyler Sealing Solutions in Middletown, DE 19709 resulted in other recordable case. Employee was maintenance Team Lead in stoppers, rubber, manufacturing.

Establishment
Datwyler Sealing Solutions
Parent company
Datwyler Sealing Solutions
Street
571 Merrimac Avenue
City
Middletown
State
DE
ZIP
19709
On-site location
Water Treatment Room
Outcome
Other recordable case (code 4)
Type
Injury (code 1)

Repairing a level sensor on the water for injection still.

The employee bled down the water system and then removed the sensor. There was still hot water and steam in the system when he pulled the sensor out which caused the burn.

Burn to upper extremities

Hot water and steam

Steam burn to arm

Job description
Maintenance Team Lead
SOC code
49-1011 — First-Line Supervisors of Mechanics, Installers, and Repairers
NAICS code
326299 — Stoppers, rubber, manufacturing
NAICS vintage
2022
Avg employees
127
Total hours worked
249287
EIN
222327412
Establishment ID
1068808
Employer case #
6189959
Date of incident
Shift started
8:00:00.000
Time of incident
10:45:00.000
Submitted
27FEB24:13:47:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.